Reference approach

Capture the accessible pallet faces, locate and decode visible symbols, remove repeated observations and reconcile them with the expected carton list.
What a pilot should establish
- Test film glare, rotated cartons, missing codes, duplicate IDs and cartons outside the visible face.
- Agree the pass, fail and uncertain outcomes before testing. Record incorrect accepts and incorrect rejects separately using an independent sample set.
Report coverage and no-reads explicitly. A successful read on the front face does not prove the identity of hidden cartons.
Outputs and line integration
Define the result required by the next process step, the time available to return it and the action for an uncertain result. Where records are needed, keep the image and decision tied to the inspected item or handling event.
Technical reference
Share pallet layouts, code sizes and expected carton records. We can define the imaging approach, integration points and a sample-based validation plan.
Evaluate this application